Ideal for

Schools & colleges
Custodial & secure facilities
Industrial units, warehouses, factories
Public buildings and leisure centres

What’s included

Stainless steel urinal body
Plastic flushing cistern
Cistern internals
Adjustable petcock
Stainless steel downpipe
Domed plastic waste outlet

Wall Mounted Urinal U01 – Standard

  • Integral Sparge for a clean, modern look

  • Waste Size – 1 – 1/2″ BSP Waste
  • Durable stainless steel construction for high-use environments

  • Eco-friendly flushing with concealed sparge system

  • Supplied complete with plastic cistern, downpipe & domed waste

  • Ideal for schools, custodial, and industrial settings

  • Price includes VAT and free delivery across the UK

Custom size?
All Urinals can be made to any size and waste position. Contact us for more information.

Price range: £400.00 through £930.00 Inc Vat

Pay later with Klarna available on checkout

Extras

Total: £400.00
SKU: U01-1 Categories: ,

Delivery

This item will be dispatched within 1–3 working days. Once dispatched, it will be sent via next working day delivery to UK mainland addresses. Please allow up to 3 working days for delivery to Scotland.
Dispatch dates are estimates and may increase during busy periods. *Subject to terms and conditions.

Description

The wall mounted urinal U01 is a robust, hygienic, and vandal-resistant solution for high-traffic washroom environments. Manufactured from high-quality stainless steel, this standard model offers long-term durability while maintaining a sleek, functional appearance. Suitable for use in schools, prisons, factories, and public facilities, the U01 ensures easy maintenance and efficient flushing performance.

This model features a seamless design with an integrated, concealed sparge system, which evenly distributes water across the urinal surface to maintain cleanliness after each flush. Designed to fix securely to the wall using pre-formed fixing holes located at either end, the U01 is quick to install and provides excellent resistance against tampering or damage.

As standard, each unit is supplied complete with a Plastic cistern, an accompanying stainless steel downpipe, and a domed plastic waste outlet. The system is compatible with both top and back water inlets, giving flexibility during installation depending on your existing plumbing layout. Whether wall-hung alone or installed in combination with multiple units for group settings, the U01 supports cost-effective washroom design without compromising on performance.

Being the manufacturer, Sterinox can also offer this unit in custom sizes to suit your specific requirements. For those seeking a tailored solution, we encourage enquiries about bespoke lengths, heights, or outlet configurations. This adaptability makes the U01 ideal for specialised commercial, custodial, and industrial applications.

Combine your order with:
CNC – Corner Capping – Combine two urinals together at a corner.
Down Pipe Cover – Protect the inlet pipe from the cistern against damage.
Splash Guard – Bolt on splash guard matched to the length of urinal.
Urinal Flushing Control – Smart automatic control of the solenoid. Flushes the cistern based on movement reducing water usage
1-1/2″ bottle trap – Prevents odours from drainage

Before You Begin

  • Ensure the wall is solid, level, and capable of supporting the urinal when in use.
  • Check that water supply and waste positions are correctly located before installation.
  • All installation work should be carried out by a competent installer using appropriate fixings for the wall type.

Recommended Mounting Heights

Measure from finished floor level to the trough:

  • Adult installation: 620 mm
  • Junior installation: 470 mm

Mark a horizontal level line across the wall at the required height.

Mounting the Urinal Body

  1. Offer the urinal body up to the wall at the marked height.
  2. On the back of the urinal ends there are two keyhole mounting slots. Mark the fixing positions on the wall.
  3. Drill and insert suitable wall plugs or anchors.
  4. Install the wall fixings, leaving the heads slightly proud to allow the urinal to locate into the keyhole slots.
  5. Lift the urinal body into position and locate onto the keyhole slots.
  6. Check the urinal body is level.
  7. Use the additional fixing holes provided to securely fix the urinal body to the wall.

Waste Connection

  1. Connect the waste outlet to the waste pipework.
  2. Ensure the waste pipe has adequate fall for drainage.
  3. Seal all joints as required.
  4. Check for leaks.

Final Checks

  • Confirm the urinal body is secure and level.
  • Ensure all fixings are tightened.
  • Run water through the system to test drainage and connections.
  • Clean the urinal body after installation.

This cistern is designed for straightforward installation using a petcock (isolation valve) and syphon. All work should be carried out by a competent installer and in accordance with current UK plumbing regulations.

  • Secure the cistern in position using suitable wall fixings, ensuring it is level before fully tightening.
  • Fit the syphon into the cistern outlet, making sure the rubber washer is positioned inside the cistern. Tighten the backnut hand-tight plus a small nip.
  • Install the inlet valve into the cistern inlet with the sealing washer located internally.
  • Fit a petcock to the incoming cold-water supply, positioning it so it remains easily accessible for isolation and maintenance.
  • Connect the water supply from the petcock to the inlet valve using 15mm pipework and appropriate fittings.
  • Fit the flush pipe to the syphon outlet, ensuring correct alignment.

Important:
Do not push the downpipe more than 25mm into the cistern, as excessive insertion can restrict syphon operation and prevent a full flush.

Once installed, slowly open the petcock, allow the cistern to fill, and check all connections for leaks. Adjust the inlet valve to achieve the correct water level and test the flush operation.

Pipework positions shown on this drawing are for guidance purposes only. It is recommended that installation of associated pipework is not carried out until the product has been delivered and checked. No responsibility will be accepted for any rework, incorrect plumbing, or resulting costs.

Pipework position dimensioned drawing. For a wall mounted urinal.

The CNC corner nose capping has a fixed length of 260mm and must be included when determining the overall length of the urinal installation. When selecting a urinal length, add 260mm to calculate the finished overall length.

Example:

  • Urinal Length 1: 900mm
  • CNC Corner Nose Capping: 260mm
  • Overall Installed Length: 1160mm

Please refer to the dimensioned drawing for a visual representation of the finished dimensions.

Dimensioned drawing for CNC Corner Capping – U01.